H1
Della Marta
High Temperature Alarm Condition
Display shows H1 and the interior temperature reading is extremely high or shows "HI".
Advertisements
Possible Causes
Door left open or not sealing, Failed compressor or Peltier module, Refrigerant leak in sealed system, Evaporator fan not running
How to Fix / Troubleshooting
Safety: Ensure the unit is in a well-ventilated area and not overheating externally.
- Door and gasket: Verify the door closes fully and the gasket seals all around. Adjust leveling feet so the door self-closes. Replace a torn or deformed door gasket if needed.
- Ventilation: Confirm there is adequate clearance around the sides and back per Della Marta specifications. Move the unit away from heat sources.
- Check fans and compressor: Listen for the compressor or Peltier module and fans running. If silent, refer to fan/compressor fault sections above.
- Thermometer check: Place an accurate thermometer inside to confirm actual temperature. If the unit is cooling but the display shows H1, suspect a sensor issue (see E1/E2).
Advertisements
Repair Difficulty
Easy
2/5
Advertisements