L1
Della Marta
Low Temperature Alarm / Thermostat Control Fault
Display shows L1 or "LO" and the interior temperature is much colder than the setpoint; bottles may be frosting.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck relay on main control PCB, Shorted temperature sensor reading too warm, Control board calibration error, Incorrect sensor placement
How to Fix / Troubleshooting
Safety: Unplug the unit before accessing controls.
- Power reset: Unplug for 10 minutes to reset the control. Restore power and monitor if L1 returns.
- Sensor placement: Ensure the cabinet sensor is not touching the evaporator coil directly; it should sense air temperature, not coil temperature.
- Check for ice: Inspect the evaporator for heavy ice buildup that could confuse temperature readings. Defrost fully if needed.
- Control board replacement: If the unit continues to overcool regardless of setpoint, replace the main control PCB which contains the thermostat logic and compressor relay.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Main Control PCB
Check Price on Amazon