Della Marta Thermostat / Temperature Control Stuck Closed

Wine cooler runs continuously and is too cold, even at the highest temperature setting.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed temperature sensor reading too warm, Stuck compressor relay on control board, Shorted thermostat circuit, Misplaced sensor touching cold coil

How to Fix / Troubleshooting

Safety: Unplug the unit before accessing sensors or the control board.

  • Check setpoint: Confirm the set temperature is correctly set and not at the coldest setting.
  • Inspect sensor placement: Ensure the cabinet sensor is not taped directly to the evaporator coil; reposition it to sense air temperature.
  • Sensor replacement: If the unit overcools and the display temperature is inaccurate, replace the cabinet NTC temperature sensor.
  • Control board: If overcooling persists, the compressor relay on the main control PCB may be stuck and the board should be replaced.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Cabinet NTC Temperature Sensor
Check Price on Amazon