dF
Dometic
Defrost Mode Indication (Not a Fault) / Defrost Cycle Active
Display shows "dF" or similar; unit may pause cooling periodically.
Advertisements
Possible Causes
Normal automatic defrost cycle, user misinterpreting status code, control board stuck in defrost due to sensor issue
How to Fix / Troubleshooting
Safety: No immediate safety risk; this is usually informational.
Steps:
- Wait cycle out: Allow 20–40 minutes for the defrost cycle to complete. The code should clear automatically and cooling should resume.
- Check for ice buildup: If the code remains for hours and cooling does not resume, unplug the unit and inspect the evaporator for heavy ice. Defrost manually if needed.
- Sensor check: Test the defrost/evaporator sensor. A faulty sensor can cause the board to remain in defrost.
- Control board: If the sensor is good but the unit remains stuck in defrost, replace the main control PCB.
Advertisements
Repair Difficulty
Easy
2/5
Advertisements