F3
Dometic Defrost Sensor / Evaporator Sensor Error (Alternate Code)

Wine cooler displays F3 and may not defrost properly; ice buildup may occur.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defrost sensor open or shorted, sensor not properly attached to evaporator, wiring harness corrosion, control board misreading sensor

How to Fix / Troubleshooting

Safety: Unplug the unit and allow any ice to melt before working near the evaporator.

Steps:

  • Access evaporator: Remove the interior rear panel to expose the evaporator and defrost sensor.
  • Check sensor mounting: Ensure the sensor is firmly clipped to the evaporator tubing and not hanging loose.
  • Test sensor: Disconnect and measure resistance. Replace the defrost/evaporator sensor if readings are abnormal.
  • Inspect harness: Repair any corroded or broken wires between the sensor and control board.
  • Replace control board: If a new sensor does not resolve F3, the defrost sensor input on the main control PCB may be defective.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Defrost / Evaporator Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements