Dometic
Light Stuck On / Door Switch Fault
Interior light stays on even when the door is closed, causing warming inside the cabinet.
Advertisements
Possible Causes
Stuck or misaligned door switch, shorted light relay on control board, door not fully closing due to gasket or hinge issue
How to Fix / Troubleshooting
Safety: Unplug the unit before working on the door switch or control board.
Steps:
- Check door closure: Ensure the door closes fully and the gasket is not preventing full closure.
- Test door switch: Press the switch manually; if the light does not go off, test the switch for continuity and replace if stuck closed.
- Control board: If the switch is good but the light remains on, the light relay on the main control PCB may be welded closed. Replace the board.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Door Switch / Reed Sensor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements