Dometic Light Stuck On / Door Switch Fault

Interior light stays on even when the door is closed, causing warming inside the cabinet.

Advertisements

Possible Causes

Stuck or misaligned door switch, shorted light relay on control board, door not fully closing due to gasket or hinge issue

How to Fix / Troubleshooting

Safety: Unplug the unit before working on the door switch or control board.

Steps:

  • Check door closure: Ensure the door closes fully and the gasket is not preventing full closure.
  • Test door switch: Press the switch manually; if the light does not go off, test the switch for continuity and replace if stuck closed.
  • Control board: If the switch is good but the light remains on, the light relay on the main control PCB may be welded closed. Replace the board.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Door Switch / Reed Sensor
Check Price on Amazon

We may earn a commission from links on this page.