E17
Electrolux
Dual-Zone Communication / Divider Damper Fault
Wine cooler shows E17 and may not maintain separate temperatures in dual-zone models.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed zone divider damper motor, Stuck or obstructed air damper, Wiring fault between damper and control board, Control board zone driver failure
How to Fix / Troubleshooting
Safety: Unplug the unit before removing interior panels.
Steps:
- 1. Confirm model type: E17 typically appears on dual-zone Electrolux wine coolers. Verify that both zones are set to appropriate temperatures.
- 2. Access damper assembly: Remove shelves and interior panels between the upper and lower zones to locate the air damper/divider assembly.
- 3. Inspect for obstruction: Ensure no bottles or racks are pressing against the damper. Check for ice buildup preventing movement.
- 4. Check wiring: Verify that the damper motor connector is secure and wires are intact.
- 5. Replace damper motor: If the damper does not move during operation and wiring is good, replace the Electrolux zone damper motor assembly.
Professional help: If a new damper does not resolve E17, the main control board's zone control circuit may be faulty and should be replaced by a technician.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Zone Divider Damper Motor