Electrolux
Lower Zone Airflow or Damper Issue
Upper zone cools properly but lower zone is warm (dual-zone model).
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed lower zone evaporator fan, Blocked air vents between zones, Stuck lower zone damper, Separate lower zone sensor failure
How to Fix / Troubleshooting
Safety: Unplug before removing interior panels.
Steps:
- 1. Check setpoints: Ensure the lower zone is set to a cooler temperature than the upper zone if desired.
- 2. Inspect vents: Make sure bottles are not blocking vents between the zones.
- 3. Listen for fan: With the unit running, listen near the lower zone for fan noise. If absent, access and test the lower zone evaporator fan.
- 4. Replace fan or damper: If the fan or damper motor is not operating, replace with the correct Electrolux part.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Lower Zone Evaporator Fan Motor
Check Price on Amazon