EuroCave
Short Cycling Control or Oversensitive Thermostat
Cabinet cycles on and off very frequently, with short run times.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Temperature sensor located too close to evaporator, Control hysteresis set too narrow (firmware), Oversized compressor for load, Poor air mixing inside cabinet
How to Fix / Troubleshooting
Safety first: Unplug the unit before accessing sensors or internal panels.
- Step 1 – Confirm actual temperature stability: Use an independent thermometer to see if wine temperature is actually fluctuating or if cycling is just audible.
- Step 2 – Check sensor placement: Ensure the cabinet NTC sensor is in its original location and not touching the evaporator coil or directly in the cold air stream.
- Step 3 – Improve air mixing: Avoid blocking internal airflow with tightly packed bottles; leave some space for circulation.
- Step 4 – Firmware/board replacement: If cycling is extreme and sensor placement is correct, the control board may have an issue with hysteresis and may need replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Cabinet Temperature NTC Sensor / Main Control Board
Check Price on Amazon
We may earn a commission from links on this page.