EuroCave
Low Internal Humidity
Cabinet interior is too dry; corks appear to be drying out despite humidity feature.
Advertisements
Possible Causes
Humidity reservoir empty or missing, Excessive ventilation or door openings, Faulty humidity sensor misreading high humidity, Overactive dehumidification due to low load
How to Fix / Troubleshooting
Safety first: No electrical work is required for basic humidity adjustments.
- Step 1 – Check humidity reservoir: If your EuroCave model uses a water tray or humidity cassette, ensure it is present and filled with distilled water.
- Step 2 – Reduce door openings: Frequent door openings can disrupt humidity balance. Minimize access where possible.
- Step 3 – Adjust bottle loading: A nearly empty cabinet can struggle to maintain humidity. Increase bottle load or add inert water containers to stabilize conditions.
- Step 4 – Verify humidity sensor: If the display shows high humidity but corks are dry, the sensor may be faulty. Replace the humidity sensor module if necessary.
Advertisements
Repair Difficulty
Very Easy
1/5
Required Part
Humidity Reservoir / Humidity Sensor Module
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements