EuroCave Keypad / Touch Control Failure

Display is lit but buttons do not respond or respond erratically.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty touch control PCB, Moisture ingress behind control panel, Loose ribbon cable, Electrostatic discharge damage

How to Fix / Troubleshooting

Safety first: Unplug the EuroCave before removing the control panel.

  • Step 1 – Clean panel surface: Wipe the control panel with a soft, slightly damp cloth to remove any residue that might affect capacitive touch.
  • Step 2 – Power reset: Disconnect power for 10 minutes, then reconnect and test button response.
  • Step 3 – Access control panel: Remove the trim and gently pull the panel forward. Inspect for moisture or corrosion on the PCB.
  • Step 4 – Reseat ribbon cable: Disconnect and reconnect the ribbon cable between the control panel and main board.
  • Step 5 – Replace control panel PCB: If specific buttons remain unresponsive, replace the control panel PCB with the correct EuroCave part.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Control Panel PCB
Check Price on Amazon