H1
EuroCave
High Temperature Alarm / Cooling Failure
Display shows H1 or a high-temperature alarm; internal temperature is significantly above setpoint.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked condenser or poor ventilation, Failed condenser fan, Refrigerant leak or low charge, Weak compressor or start device failure
How to Fix / Troubleshooting
Safety first: Disconnect power before cleaning coils or accessing the rear compartment.
H1 indicates the cabinet is too warm and cannot reach the set temperature.
- Step 1 – Check door seal and usage: Ensure the door closes fully and the gasket is intact. Avoid frequent or prolonged door openings.
- Step 2 – Verify installation: Confirm adequate clearance around the cabinet and that it is not installed in a very hot room (above the specified ambient range).
- Step 3 – Clean condenser coil: Remove the rear lower panel and gently vacuum or brush dust from the condenser. A clogged condenser severely reduces cooling.
- Step 4 – Check condenser fan: With power restored, verify that the rear fan runs when the compressor is on. If not, see the condenser fan fault procedure.
- Step 5 – Monitor cooling: After cleaning and ensuring ventilation, allow 12–24 hours for temperatures to stabilize. Use an independent thermometer to verify.
- Step 6 – Suspect sealed system issues: If the compressor runs continuously, the condenser is clean, and temperatures remain high, there may be a refrigerant leak or weak compressor. This requires a certified refrigeration technician.
Advertisements
Repair Difficulty
Hard
4/5