EuroCave Interior LED Lighting Failure

Interior light does not turn on when the door is opened, but the unit cools normally.

Advertisements

Possible Causes

Burned-out LED module or strip, Faulty door switch not signaling light circuit, Loose wiring to light assembly, Failed light driver on control board

How to Fix / Troubleshooting

Safety first: Unplug the EuroCave before accessing the light assembly or control panel.

  • Step 1 – Check light settings: Some models allow disabling the interior light via the control panel. Ensure it is not turned off in the menu.
  • Step 2 – Test door switch: If the unit also fails to register door open/close (no alarm, no display change), the door switch may be faulty. See door switch troubleshooting.
  • Step 3 – Access light module: Remove the light cover inside the cabinet (usually clipped or screwed). Inspect the LED module and connector.
  • Step 4 – Reseat connector: Disconnect and reconnect the light wiring harness. Look for corrosion or loose pins.
  • Step 5 – Replace LED module: If the module is visibly damaged or still does not light, replace it with the correct EuroCave LED light assembly.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Interior LED Light Module
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements