Fagor Condenser Fan Failure

Condenser fan at the rear does not run, causing the compressor to overheat and poor cooling.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed condenser fan motor, Obstruction in fan blades, Loose or broken fan wiring, Faulty fan output on main PCB

How to Fix / Troubleshooting

Safety: Unplug the wine cooler before working at the rear.

Steps:

  • Access fan: Remove the rear lower panel to expose the condenser fan near the compressor.
  • Check for obstructions: Remove any debris or wires blocking the fan blades.
  • Test motor: Spin the blades by hand; they should move freely. Measure motor resistance; an open circuit indicates failure.
  • Check wiring: Ensure the fan connector is secure and wires are intact.
  • Replace fan motor: Install a new Fagor condenser fan motor if defective.
  • Main board: If the motor is good but never receives power when the compressor runs, the main PCB may be faulty and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Condenser Fan Motor
Check Price on Amazon