Fagor
Display Backlight / UI Power Issue
Display is blank or very dim, but the compressor and fans still run.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed display backlight LEDs, Loose connector between UI and main board, Partial failure of UI PCB, Low voltage from main board to UI
How to Fix / Troubleshooting
Safety: Unplug the wine cooler before removing the control panel.
Steps:
- Check for faint display: Shine a flashlight at an angle; if you can see numbers faintly, the backlight has failed.
- Inspect connections: Remove the control panel and verify that the ribbon cable and connectors between the UI and main board are secure.
- Replace UI PCB: If connections are good and the display remains blank or dim, replace the Fagor user interface/display board.
- Main board: If a new UI does not restore the display, the main PCB may not be supplying correct voltage and should be replaced.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
User Interface / Display PCB
Check Price on Amazon