Fagor Single-Zone Cooling Failure in Dual-Zone System

Dual-zone wine cooler has one zone cooling properly while the other zone is warm.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed evaporator fan in affected zone, Faulty zone temperature sensor, Air duct blockage between zones, Control board not energizing zone valve or damper (if equipped)

How to Fix / Troubleshooting

Safety: Unplug the unit before accessing interior panels.

Steps:

  • Compare zones: Note which zone (upper or lower) is not cooling.
  • Check fan operation: Listen for fan noise in each zone when the compressor is running. Access the interior panel of the warm zone and verify the fan runs. Replace the fan motor if it does not.
  • Inspect air ducts: Ensure vents between zones are not blocked by bottles or debris.
  • Test zone sensor: Measure resistance of the affected zone's cabinet sensor and compare to the working zone. Replace if readings differ significantly.
  • Control board: If fans and sensors are good, the main PCB may not be controlling the zone correctly and may need replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Zone Evaporator Fan Motor
Check Price on Amazon