E9
Fagor High Temperature Alarm / Over-Temperature Fault

Wine cooler shows E9 and the compressor may not start; sometimes accompanied by beeping.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Prolonged door open, Failed condenser fan motor, Dirty condenser coil causing overheating, Refrigerant leak or low charge, Faulty temperature sensor misreading high temperature

How to Fix / Troubleshooting

Safety: Always unplug the unit before cleaning coils or accessing fans.

Immediate actions:

  • Check door seal and usage: Ensure the door is fully closing and not being left open. Inspect the gasket for gaps or damage.
  • Allow recovery time: If the door was recently open for loading, close it and allow 12–24 hours for temperature to stabilize. E9 may clear automatically.
  • Clean condenser coil: Pull the unit away from the wall. Remove the rear lower panel to access the condenser. Use a soft brush and vacuum to remove dust and lint from the coil and surrounding area.
  • Check condenser fan: With the panel off, briefly power the unit and observe the condenser fan (near the compressor). It should run whenever the compressor runs. If not spinning or noisy, unplug and replace the fan motor.
  • Verify ambient conditions: Ensure the cooler is not installed in a very hot location (e.g., next to an oven or in direct sunlight) beyond Fagor's specified ambient range.
  • Sensor check: If the interior feels cold but E9 persists, test the cabinet temperature sensor as described for E1. Replace if misreading.
  • Refrigerant issue: If the compressor and fans run but the unit does not cool and E9 remains, a sealed system problem (leak, restriction, or weak compressor) is likely. This requires a licensed refrigeration technician.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Condenser Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.