Lo
Fagor Low Temperature Display / Sensor Under-Range

Display shows "Lo" for temperature and compressor may not run; interior may be too cold or normal.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Cabinet sensor reading below minimum range, Sensor shorted, Control board misinterpreting sensor, Actual freezing conditions inside cabinet

How to Fix / Troubleshooting

Safety: Unplug the unit before sensor testing.

Steps:

  • Check actual temperature: Place an accurate thermometer inside the cooler to verify the real temperature. If it is normal but display shows "Lo", suspect a sensor or board issue.
  • Test cabinet sensor: Measure resistance at room temperature. A very low resistance indicates a shorted sensor. Replace with a correct Fagor NTC sensor.
  • Inspect wiring: Look for damaged insulation or wires touching each other or metal surfaces.
  • Control board: If sensor and wiring are good, replace the main control board.