Fagor
Evaporator Fan Control Issue
Interior fan runs constantly even when the compressor is off, or never runs at all.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck fan relay on main PCB, Faulty evaporator fan motor, Incorrect door switch signal, Wiring short causing constant power
How to Fix / Troubleshooting
Safety: Unplug the unit before accessing fans or control boards.
Steps:
- Observe behavior: Note whether the fan runs with the door open or closed and whether it ever stops.
- Check door switch: A faulty switch may cause the fan to run or stop at the wrong times. Test and replace if needed.
- Test fan motor: Access the evaporator fan and measure resistance. Replace the motor if open or seized.
- Inspect wiring: Look for signs of a short that could be feeding constant power to the fan.
- Main PCB: If wiring and motor are good but control is incorrect, replace the main control board.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Evaporator Fan Motor
Check Price on Amazon
We may earn a commission from links on this page.