Fagor
Compressor Not Running
Wine cooler not cooling at all; interior light works but temperature does not drop and compressor is silent.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed main control board compressor relay, Defective compressor start relay or overload, Open thermal protector on compressor, Broken wiring to compressor
How to Fix / Troubleshooting
Safety: Unplug the wine cooler and wait several minutes before accessing the rear. High voltage is present when powered.
Steps:
- Confirm symptoms: Listen for any humming or clicking from the compressor area when the unit is plugged in and calling for cooling. If completely silent, suspect control or wiring.
- Access rear components: Remove the rear lower panel to expose the compressor, start relay, overload, and wiring.
- Check wiring: Inspect the harness from the main PCB to the compressor for loose connectors or burnt wires. Reseat all plugs.
- Test start relay/overload: Remove the relay/overload assembly from the compressor. Check for continuity through the overload and appropriate resistance through the PTC relay. Replace if open or physically damaged.
- Control board output: With extreme caution and only if qualified, test for compressor voltage at the board output when cooling is requested. No voltage with correct inputs indicates a bad main PCB.
- Replace faulty parts: Install a new Fagor compressor start relay/overload or main control board as indicated by tests.
Note: If you are not experienced with live voltage testing, contact a professional technician.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Compressor Start Relay and Overload Protector
Check Price on Amazon