Fisher & Paykel No Power to Control Board

Display is completely blank; unit appears dead, but outlet has power.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blown internal fuse on PCB, failed power supply section of main board, loose mains connector, damaged power cord

How to Fix / Troubleshooting

Safety: Unplug the appliance before opening any panels. Capacitors on the PCB can retain charge; avoid touching components unnecessarily.

Steps to diagnose:

  • Verify outlet: Test the outlet with another device.
  • Inspect power cord: Check for visible damage. Replace if compromised.
  • Access main PCB: Remove rear panel and locate the control board. Check that the mains connector is fully seated.
  • Check fuses: Look for any onboard fuses and test continuity. Replace only with identical type and rating.
  • Board replacement: If fuses are intact but no low-voltage output is present, replace the main control board.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control Board / Power Cord