Fisher & Paykel Stuck or Failed Temperature Sensor

Display works but temperature reading does not change over time, even when the interior clearly warms or cools.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Thermistor shorted at a fixed resistance, sensor disconnected and reading default value, control board ADC failure

How to Fix / Troubleshooting

Safety: Unplug the unit before accessing sensors or the control board.

Steps to correct:

  • Compare with thermometer: Place an accurate thermometer inside and compare to the displayed temperature.
  • Inspect sensor: Access the cabinet thermistor and check for damage or disconnection.
  • Test resistance: Measure thermistor resistance at two different temperatures (e.g., room temperature and after cooling). If readings do not change, replace the sensor.
  • Control board: If a new sensor does not resolve the issue, the main PCB's sensor input may be faulty and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Cabinet Temperature Sensor / Main Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements