AL
Fisher & Paykel High Temperature Alarm

Wine cooler displays AL or an alarm icon with beeping; internal temperature is significantly above setpoint.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Door left open, recent warm loading, power outage, failed evaporator fan, sealed system fault

How to Fix / Troubleshooting

Safety: No immediate electrical work is required; basic checks can be done with power on. Unplug before removing panels.

Steps to address AL:

  • Confirm door closure: Ensure the door is fully closed and the gasket is sealing properly.
  • Allow recovery time: If the door was recently open for an extended period or many warm bottles were added, allow 12–24 hours for temperature to recover.
  • Check for airflow: Listen for the evaporator fan running when the compressor is on. If silent, investigate fan motor and wiring.
  • Inspect condenser: Clean the condenser coil and verify the condenser fan is operating to ensure efficient cooling.
  • Monitor temperature: Use an independent thermometer to verify actual cabinet temperature. If the unit cannot reach setpoint after cleaning and checks, a sealed system or sensor fault may be present and require professional service.
Advertisements

Repair Difficulty

Medium 3/5
Advertisements