E3
Fisher & Paykel Defrost Sensor / Evaporator Sensor Fault (Zone-Specific)

Wine cooler shows E3 and may not defrost correctly; frost buildup in one or both zones.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defrost thermistor failure on one evaporator, sensor dislodged from coil, wiring harness damage, control board input failure

How to Fix / Troubleshooting

Safety: Disconnect power and allow any ice to melt before handling the evaporator area.

Steps to address E3:

  • Identify affected zone: Check which zone is frosting excessively or not maintaining temperature; that zone's evaporator sensor is suspect.
  • Access evaporator: Remove shelves and the rear panel in the affected zone to expose the evaporator coil and sensor.
  • Inspect sensor placement: Ensure the sensor is clipped firmly to the coil or tubing and not hanging loose. Reattach if necessary.
  • Check wiring: Look for brittle or cracked insulation, especially where wires pass through foam or metal. Repair or replace damaged sections.
  • Test sensor: With power off, disconnect and measure resistance. Replace the sensor if readings are open, shorted, or out of spec.
  • Reassemble and monitor: After replacing the sensor, reassemble panels, restore power, and monitor for recurrence of E3.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Defrost / Evaporator Thermistor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements