E8
Fisher & Paykel Zone Damper / Air Diverter Fault (Dual-Zone Models)

Wine cooler displays E8 and may not maintain separate temperatures in dual zones; zones may equalize.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck or broken air damper motor, damper flap obstructed by ice, wiring harness fault to damper, control board output failure

How to Fix / Troubleshooting

Safety: Unplug the unit before accessing internal ducting or damper assemblies.

Steps to address E8:

  • Observe temperature behavior: If both zones drift toward the same temperature, the air damper between zones may be stuck open or closed.
  • Access damper assembly: Remove shelves and interior trim panels where the zones connect (often at the rear or side wall) to locate the damper housing.
  • Inspect for ice or obstruction: Look for ice buildup or foreign objects blocking the damper flap. Defrost and clear obstructions.
  • Check damper motor: With power off, inspect the motor and gears for damage. Verify wiring is intact and connectors are secure.
  • Functional test (advanced): With the unit powered and panels temporarily off, change zone setpoints and listen/feel for damper movement. If no movement and voltage is present at the motor, replace the damper motor assembly.
  • Control board check: If the motor is good but never receives a control signal, the main PCB may be faulty.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Zone Air Damper Motor Assembly