Fisher & Paykel
Poor Cooling Performance / Sealed System Inefficiency
Wine cooler runs constantly but does not reach set temperature; compressor and fans are running almost all the time.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Low refrigerant charge from micro-leak, partially restricted capillary tube, inefficient compressor, heavily fouled condenser coil
How to Fix / Troubleshooting
Safety: Unplug before cleaning or inspecting internal components. Sealed system work must be done by a licensed technician.
Steps to check:
- Clean condenser: Remove rear lower panel and clean condenser fins thoroughly.
- Verify condenser fan: Ensure the fan runs whenever the compressor is on.
- Check door seals and usage: Inspect gaskets for leaks and minimize door openings.
- Monitor frost pattern: With the inner rear panel removed (if accessible), observe the evaporator after 15–20 minutes of run time. A partial frost pattern (only at the inlet) suggests low charge or restriction.
- Call a professional: If basic airflow and sealing issues are resolved and performance is still poor, schedule sealed system service with an authorized Fisher & Paykel technician.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Compressor / Capillary Tube / Evaporator Coil
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements