E10
Gaggenau Low-Voltage Power Supply Fault

Display shows E10 and the interior light or other low-voltage functions may not operate correctly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed low-voltage power supply section on control board, Shorted LED light module, Shorted fan or accessory load, Loose neutral or ground connection

How to Fix / Troubleshooting

Safety: Unplug the unit before testing for shorts or removing the control board. Use caution when working around mains voltage.

Troubleshooting steps:

  • 1. Observe symptoms: Note which low-voltage components (display, lights, fans, sensors) are not working. This can help identify a shorted load.
  • 2. Inspect LED light modules: Remove interior light covers and check for signs of overheating or moisture. Disconnect the light harness and see if E10 clears after a power reset.
  • 3. Check fans and accessories: Disconnect evaporator and condenser fans one at a time (with power off), then restore power to see if the error disappears, indicating a shorted motor.
  • 4. Inspect control board: Access the main control and look for burnt traces or components in the low-voltage section. Measure output voltages if you have the proper tools and training.
  • 5. Replace faulty load: If a specific light module or fan is identified as shorted, replace it with the correct Gaggenau part.
  • 6. Replace control board if needed: If no external load is shorted and the board does not provide correct low-voltage outputs, replace the main control board.
  • 7. Reassemble and test: After repairs, reconnect all components, restore power, and verify that E10 is cleared and all functions operate normally.

Warning: Do not bypass fuses or protective devices on the control board; this can create a fire hazard.

Advertisements

Repair Difficulty

Hard 4/5