Wine cooler shows E17 and may not cool; compressor and fans may be off while lights and display work.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety: Ensure adequate ventilation around the appliance before restarting. Disconnect power before internal inspection.
Steps:
- 1. Check ventilation: Confirm that front or rear vents are not blocked and that installation follows Gaggenau clearance requirements.
- 2. Allow unit to cool: Leave the cooler off with the door slightly open for 30–60 minutes to dissipate heat.
- 3. Power reset: Restore power and see if E17 clears. If it returns quickly, proceed with further checks.
- 4. Inspect overtemperature sensor: Some models use a dedicated safety sensor near the compressor or condenser. Test resistance and replace if out of spec.
- 5. Inspect condenser fan and coils: Ensure the condenser fan runs and coils are clean. Overheating from poor airflow can trigger protection.
- 6. Replace control board if stuck in lockout: If all hardware is normal but the board will not exit protection mode, the control may be defective.
Note: Repeated overtemperature events can damage wine; consider using an external thermometer to verify actual cabinet temperature after repair.
Repair Difficulty
Required Part
We may earn a commission from links on this page.