Gaggenau Non-Running Compressor (Electrical Control Issue)

Wine cooler is completely warm; compressor does not run at all, but interior lights and display work.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed compressor start relay/PTC, Faulty main control board compressor relay, Open thermal overload on compressor, Loose wiring at compressor terminals

How to Fix / Troubleshooting

Safety: Disconnect power before accessing the compressor compartment. Capacitors and terminals can be hazardous.

Steps:

  • 1. Listen for compressor: With the unit powered (briefly), check if you hear a humming or clicking from the compressor. Then disconnect power before touching anything.
  • 2. Access rear compartment: Remove the lower rear panel to expose the compressor and start device.
  • 3. Inspect start relay/PTC: Remove the start device from the compressor. Look for burn marks or melted plastic. Replace if damaged.
  • 4. Check wiring: Ensure all wires to the compressor and start device are secure and not corroded.
  • 5. Test compressor windings: With the start device removed and power off, measure resistance between compressor terminals. If readings are open or shorted, the compressor is likely failed and requires professional replacement.
  • 6. Evaluate control board: If the compressor and start device are good, the main control board may not be sending power to the compressor. Replace the board if confirmed.

Warning: Compressor replacement and refrigerant handling must be done by a licensed technician.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Compressor Start Relay / PTC Device
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements