Gaggenau
Compressor or Condenser Vibration Noise
Wine cooler makes loud humming or buzzing noise from the rear, especially when the compressor runs.
Advertisements
Possible Causes
Loose compressor mounting grommets, Condenser coil touching cabinet, Vibrating copper tubing, Unit not leveled causing resonance
How to Fix / Troubleshooting
Safety: Unplug the unit before reaching into the compressor compartment. Metal edges can be sharp.
Steps:
- 1. Level the appliance: Use a spirit level to ensure the wine cooler is level front-to-back and side-to-side. Adjust leveling feet as needed.
- 2. Inspect compressor mounts: Access the rear compartment and check rubber grommets under the compressor. Replace if cracked or missing.
- 3. Secure tubing: Gently move copper lines away from cabinet walls or each other if they are touching and vibrating. Use foam sleeves or clips to prevent contact.
- 4. Check condenser coil: Ensure the condenser is firmly mounted and not rattling against the frame.
- 5. Test noise: Restore power and listen. Make small adjustments until noise is minimized.
Warning: Do not bend refrigerant lines sharply or apply excessive force; this can cause leaks.
Advertisements
Repair Difficulty
Easy
2/5