Gaggenau Overcooling / Thermostat Control Failure

Wine cooler runs continuously and gets too cold; bottles may be colder than the set temperature.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted cabinet temperature sensor, Stuck relay on main control board, Incorrect sensor placement touching evaporator, Faulty control board logic

How to Fix / Troubleshooting

Safety: Unplug the unit before accessing sensors or the control board.

Steps:

  • 1. Verify temperature: Use an accurate thermometer to confirm actual cabinet temperature versus the setpoint.
  • 2. Inspect cabinet sensor: Locate the NTC sensor in the compartment wall. Ensure it is not touching the evaporator or a cold air outlet, which can cause false low readings.
  • 3. Test sensor resistance: Disconnect the sensor and measure resistance at known temperature. Replace if readings are out of spec or if the sensor is shorted.
  • 4. Check control board relay: If the compressor relay is stuck closed, the compressor may run continuously. Inspect the board and replace if the relay is welded or the board is damaged.
  • 5. Reassemble and test: After replacing components, monitor operation over several hours to ensure proper cycling.

Tip: Overcooling can dry out corks; resolve this issue promptly to protect your wine.