H1
GE High Temperature Alarm Condition

Display shows H1 and the cabinet temperature is very high; wine is warm.

Advertisements

Possible Causes

Door left open or not sealing, recent warm loading of bottles, failed compressor, condenser fan not running, refrigerant leak or sealed system failure

How to Fix / Troubleshooting

Safety: No internal electrical work is required for basic checks; unplug only if removing panels.

  • Check door: Ensure the door is fully closing and the gasket is intact and clean. Remove any bottles blocking closure.
  • Allow recovery: If you recently loaded many warm bottles, allow 12–24 hours for the temperature to stabilize. Keep the door closed as much as possible.
  • Ventilation and fan: Verify that the unit has proper clearance and that the condenser fan (if equipped) runs when the compressor is on. Clean dust from the condenser coils.
  • Compressor operation: Listen for the compressor running. If it is not running at all, or runs but the cabinet never cools, there may be a sealed system issue or failed compressor.
  • When to call a technician: If H1 persists after cleaning, ensuring door seal, and allowing recovery time, contact a professional for sealed system diagnosis.
Advertisements

Repair Difficulty

Easy 2/5