L1
GE Low Temperature Alarm Condition

Display shows L1 and the cabinet temperature is very low; bottles may be too cold.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect temperature setting, failed thermistor reading too warm, control board stuck in cooling mode, compressor relay welded closed

How to Fix / Troubleshooting

Safety: Unplug the unit before removing panels.

  • Verify settings: Check that the set temperature is appropriate for wine storage (typically 45–65°F depending on zone). Adjust if set too low.
  • Power reset: Unplug for 5 minutes, then restore power to clear any temporary control glitch.
  • Check thermistor: If the unit continues to overcool, test the cabinet thermistor as described for sensor errors. Replace if out of spec.
  • Control board: If the thermistor is good but the compressor runs almost constantly, the main control board relay may be stuck. Replace the control board.

Monitor temperature after repair to ensure it stabilizes at the setpoint.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Main Control Board