GE
Overcooling / Temperature Control Failure
Wine cooler is too cold; bottles are near freezing even at normal settings.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed cabinet thermistor reading too warm, stuck compressor relay on control board, miscalibrated control board
How to Fix / Troubleshooting
Safety: Unplug the unit before accessing internal components.
- Verify settings: Confirm the temperature is not set too low. Adjust to a higher setpoint and monitor for several hours.
- Power reset: Unplug for 5–10 minutes to reset the control board, then restore power.
- Test thermistor: Access the cabinet thermistor and measure resistance at known temperature. Replace if readings are out of GE’s specified range.
- Replace control board: If the thermistor is good but the compressor runs excessively and temperature remains too low, replace the main control board.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Cabinet Thermistor
Check Price on Amazon
We may earn a commission from links on this page.