Grundig
Zone Separation or Damper Failure
Dual-zone wine cooler has both zones at the same temperature despite different setpoints.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed air damper between zones stuck open, Partition insulation damaged, Single evaporator fan not distributing air correctly, Control board not actuating damper
How to Fix / Troubleshooting
Safety: Unplug the appliance before removing internal panels.
- Check actual temperatures: Use thermometers in both zones to confirm they are equal.
- Inspect partition: Remove shelves and panels to access the partition between zones. Look for gaps or missing insulation.
- Check damper operation: If equipped, observe the Grundig zone air damper while changing setpoints. It should move to adjust airflow. If stuck, clean or replace it.
- Verify fan operation: Ensure the evaporator fan runs properly to allow correct distribution.
- Replace faulty damper or PCB: If the damper does not receive power or respond, the actuator or main PCB may need replacement.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Zone Air Damper
Check Price on Amazon
We may earn a commission from links on this page.