E8
Grundig
Compressor Drive or Inverter Fault (if equipped)
Display shows E8 and the compressor does not run; the unit remains warm.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty main control board compressor relay, Defective inverter module on inverter-driven models, Open wiring between PCB and compressor, Internal compressor electrical fault
How to Fix / Troubleshooting
Safety: Disconnect mains power. Sealed system and inverter work should be performed by qualified personnel.
- Check power to unit: Confirm the outlet supplies correct voltage and the power cord is intact.
- Inspect wiring: Remove the rear panel and verify all connectors between the main PCB, inverter (if present), and compressor are secure.
- Listen for relay click: When powered and calling for cooling, you should hear a relay click on the PCB. No click may indicate a failed relay or control board.
- Measure compressor windings: With power off and wires removed from the compressor, measure resistance between terminals. Compare to Grundig specs. A short to ground or open winding indicates a bad compressor.
- Replace control components: If the compressor tests good, replace the Grundig main control board or inverter module as applicable.
- Call a technician for compressor replacement: If the compressor is electrically faulty, a sealed system technician must replace and recharge the system.