E9
Grundig Control Panel or Keypad Fault

Display shows E9 and the unit beeps; temperature cannot be adjusted properly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck touch keys on control panel, Moisture ingress behind display, Damaged control PCB membrane, Loose ribbon cable between UI and main board

How to Fix / Troubleshooting

Safety: Unplug the wine cooler before removing the control panel or display assembly.

  • Dry the control area: If condensation or liquid has contacted the panel, allow it to dry completely. Do not use heat guns.
  • Inspect control panel: Remove the front control panel carefully. Check for cracks, corrosion, or moisture on the PCB.
  • Check ribbon cable: Ensure the flat cable between the user interface (UI) board and main PCB is fully seated and not damaged.
  • Clean contacts: Use isopropyl alcohol and a soft brush to clean any residue on the control PCB.
  • Test buttons: With the panel reconnected and power restored, test each key. If some keys remain unresponsive or E9 persists, the panel is likely defective.
  • Replace UI board: Install a new Grundig control panel / user interface board and reassemble the fascia.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Control Panel / User Interface Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements