Grundig Door Switch Stuck Closed

Interior light stays on even when the door is closed, causing heating inside the cabinet.

Advertisements

Possible Causes

Misaligned door magnet and reed switch, Stuck mechanical door switch, Shorted door switch wiring, Control board not recognizing door closed state

How to Fix / Troubleshooting

Safety: Unplug the wine cooler before adjusting the door switch or magnet.

  • Check door alignment: Ensure the door closes fully and is not warped.
  • Inspect magnet and reed switch: Verify that the door magnet is present and aligned with the reed switch location in the frame. Replace missing or weak magnets.
  • Test switch: Use a multimeter to check the reed switch or mechanical switch for proper open/close operation when the door is moved.
  • Replace faulty components: Install a new Grundig door reed switch or magnet if defective. If the switch works but the light remains on, the main PCB may be at fault.