Grundig
Refrigerant Leak in Sealed System
Unusual sweet or solvent-like odor and loss of cooling performance.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Pin-hole leak in evaporator, Corroded condenser tubing, Poorly brazed joint at compressor or filter drier, Mechanical damage to refrigerant lines
How to Fix / Troubleshooting
Safety: Unplug the wine cooler. Do not attempt to repair the sealed system yourself; refrigerant handling requires certification.
- Visual inspection: Look for oily residue on copper lines, around the evaporator, or near the compressor connections—this often indicates a leak.
- Check cooling performance: If the compressor runs continuously but the cabinet does not cool, a leak is likely.
- Do not operate with a suspected leak: Running the compressor with low refrigerant can cause further damage.
- Contact a licensed technician: A professional must locate the leak, repair the tubing, replace the filter drier, evacuate, and recharge the system to Grundig specifications.
Advertisements
Repair Difficulty
Professional Required
5/5