F3
Hisense Zone Evaporator Sensor / Frost Sensor Fault

Display shows F3 and one zone of the wine cooler shows wildly fluctuating temperatures.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective zone evaporator NTC, Sensor detached from coil, Harness damage near evaporator, PCB sensor input failure

How to Fix / Troubleshooting

Unplug the unit before removing panels. F3 often indicates a problem with a zone-specific evaporator sensor.

  • Identify affected zone: Check which zone temperature is unstable or not responding to setpoint changes.
  • Access evaporator for that zone: Remove shelves and the inner rear panel for the affected zone.
  • Check sensor placement: Ensure the sensor is firmly attached to the evaporator tubing and not hanging loose.
  • Test and replace: Measure resistance and compare to other sensors. Replace with a Hisense-compatible evaporator NTC if faulty.

Persistent F3 after sensor replacement suggests a main PCB issue that should be handled by a professional.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Zone Evaporator NTC Sensor
Check Price on Amazon