Hisense
No Power / Main Power Circuit Failure
Wine cooler is completely dead, no lights or display, does not respond to buttons.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blown internal fuse on main PCB, Faulty power cord, Tripped household breaker, Failed main control PCB power supply section
How to Fix / Troubleshooting
Ensure safety by unplugging before opening panels.
- Check outlet and breaker: Test the wall outlet with another device and reset any tripped breakers or GFCI outlets.
- Inspect power cord: Look for visible damage. If the cord is cut or burned, it must be replaced.
- Access main PCB: Remove the rear lower cover. Look for an inline fuse or board-mounted fuse. Test continuity with a multimeter and replace with the same rating if blown.
- Inspect PCB: Check for burnt components or bulging capacitors in the power supply area.
If replacing a fuse results in immediate failure again, or if the PCB shows damage, the main control board should be replaced by a professional.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Main Control PCB