E2
hOmeLabs Ambient / Upper Zone Temperature Sensor Failure

Display shows E2 and temperature readings are erratic or the unit overcools/undercools.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed ambient/upper zone thermistor, Loose thermistor connector at control board, Damaged sensor wiring from door hinge movement

How to Fix / Troubleshooting

Safety warning: Always disconnect power before opening any panels.

Steps:

  • Confirm the code: Verify that E2 appears consistently and not just during startup.
  • Locate the ambient/upper sensor: On single-zone hOmeLabs units, this may be near the top of the interior side wall. On dual-zone models, E2 often refers to the upper zone sensor, usually clipped behind the upper evaporator cover.
  • Remove interior trim: Take out the shelves and gently remove the plastic cover where the sensor is mounted. Look for a small probe or plastic-encased sensor with two wires.
  • Inspect wiring: Check for frayed insulation, pinched wires near the door frame, or moisture intrusion. Repair minor insulation damage with electrical tape; replace the harness if conductors are broken.
  • Check connector at control board: Access the rear lower panel, locate the main control board, and find the connector labeled for the upper/ambient sensor. Unplug and replug it to ensure a solid connection.
  • Test with a multimeter: Measure resistance of the sensor at room temperature. Compare to the expected NTC curve (typically 5–10 kΩ at 77°F). If reading is far off, open, or shorted, the sensor is defective.
  • Replace sensor: Install a new hOmeLabs upper zone/ambient temperature sensor, routing the cable along the original path and securing it away from moving parts and sharp edges.
  • Power up: Reassemble panels, restore power, and verify that E2 is cleared and temperature readings stabilize.

Note: Persistent E2 with a known-good sensor suggests a faulty main control board.