E8
hOmeLabs LED Lighting Circuit Fault

Display shows E8 and the interior light or display backlight may not function correctly.

Advertisements

Possible Causes

Shorted LED light strip, Failed LED driver circuit on main board, Damaged light harness in door frame

How to Fix / Troubleshooting

Disconnect power before working on lighting circuits.

  • Check basic operation: Open and close the door to see if the interior LED light attempts to turn on. Note any flickering or dim operation.
  • Inspect LED strip: Locate the interior LED light strip (often mounted along the side wall or top). Look for burn marks, discoloration, or physical damage.
  • Check wiring: Follow the light harness to its connector. Ensure it is firmly plugged into the main board or intermediate connector.
  • Test with a known-good strip (if available): If you have access to a compatible LED strip, temporarily connect it to see if E8 clears and lighting returns.
  • Replace faulty components: If the strip is visibly damaged or fails to light, replace it with a hOmeLabs LED light strip assembly. If multiple strips test bad, the LED driver on the main board may be faulty and the main control board may need replacement.
  • Reassemble and test: After replacement, restore power and verify that E8 is cleared and lighting works normally.

Note: Avoid touching LED contacts with bare hands to reduce corrosion risk.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

LED Light Strip
Check Price on Amazon

We may earn a commission from links on this page.