hOmeLabs Control Board Not Activating Compressor Circuit

Wine cooler has power (lights/display on) but compressor and fan never start.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed compressor relay on main board, Loose compressor harness connector, Faulty temperature sensor preventing call for cooling

How to Fix / Troubleshooting

Unplug the unit before touching wiring.

  • Confirm temperature setting: Ensure the set temperature is lower than room temperature so the unit should be calling for cooling.
  • Check door switch: Some models inhibit cooling if the door switch is faulty. Press the door switch manually and see if the fan or compressor attempts to start.
  • Inspect compressor connector: At the compressor, verify that the harness is fully seated on the start relay/overload assembly.
  • Board relay check: Access the main control board and look for the compressor relay. Inspect for burn marks or cracked solder joints. If the relay is visibly damaged, replace the main control board.
  • Sensor sanity check: If the board believes the cabinet is already cold due to a bad sensor, it may not start the compressor. Compare displayed temperature to an internal thermometer and replace the cabinet thermistor if readings are inaccurate.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control Board (PCB)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements