F2
Hoover
Lower Zone Temperature Control Fault
Wine cooler shows F2 and the lower zone does not maintain the set temperature.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Lower zone NTC sensor failure, Lower zone fan not operating, Ice blocking lower evaporator, Main PCB lower zone control failure
How to Fix / Troubleshooting
Safety first: Unplug the unit before accessing lower zone panels or fans.
Steps to resolve F2:
- Check loading: Avoid packing bottles tightly against the rear wall or vents in the lower zone.
- Inspect lower zone fan and evaporator: Remove the lower internal panel to check for ice buildup and verify fan operation. Defrost fully if ice is present.
- Test lower zone sensor: Locate the lower zone NTC sensor and measure resistance. Replace if open, shorted, or out of specification.
- Verify wiring: Ensure the lower zone fan and sensor connectors are firmly seated on the main PCB.
- Replace PCB if needed: If all components test good and F2 persists, the lower zone control on the main PCB may be faulty and require replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Lower Zone NTC Temperature Sensor
Check Price on Amazon
We may earn a commission from links on this page.