H1
Hoover
High Temperature Alarm / Cooling Failure
Wine cooler displays H1 and the internal temperature is too high; bottles feel warm.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Condenser coil clogged with dust, Condenser fan not running, Refrigerant leak or low charge, Failed compressor or start device
How to Fix / Troubleshooting
Safety first: Unplug the wine cooler before cleaning or accessing the rear compartment. Do not attempt to open the sealed refrigeration system.
Steps to address H1:
- Check ambient conditions: Ensure the cooler is installed in a room within Hoover's specified temperature range and has adequate ventilation around the sides and rear.
- Clean condenser coils: Remove the rear lower panel (if fitted) and use a soft brush and vacuum to remove dust from the condenser coil. Blocked coils greatly reduce cooling efficiency.
- Verify condenser fan operation: With the unit powered (briefly), check that the condenser fan runs when the compressor is on. If not, unplug and inspect the fan for obstructions or damage. Replace the Hoover-compatible condenser fan motor if it does not run.
- Check compressor: When powered, the compressor should hum and vibrate slightly. If it is hot and not running, suspect a failed start relay/PTC or compressor fault (see E5).
- Monitor temperature: After cleaning and verifying fans, allow 12–24 hours for the temperature to stabilize. If H1 persists and the unit does not cool, there may be a refrigerant leak or internal blockage, which requires a certified refrigeration technician.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Condenser Fan Motor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements