Hoover Reduced Cooling Capacity

Wine cooler runs continuously but does not reach set temperature; interior is cool but not cold enough.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Dirty condenser coils, Weak condenser fan, Partial refrigerant leak, Door gasket not sealing properly

How to Fix / Troubleshooting

Safety first: Unplug the appliance before cleaning or adjusting components.

Steps to improve cooling:

  • Clean condenser: Remove dust from the condenser coil at the rear using a soft brush and vacuum. This is one of the most common causes of poor cooling.
  • Check condenser fan: Ensure the fan runs smoothly and at full speed when the compressor is on. Replace the Hoover-compatible condenser fan motor if it is slow, noisy, or intermittent.
  • Inspect door gasket: Close the door on a sheet of paper and gently pull. If it slides out easily all around, the gasket may be worn or misaligned. Warm the gasket with a hairdryer (on low) and reshape, or replace the door gasket.
  • Check installation: Ensure adequate ventilation space around the cooler and that it is not installed in a very hot environment beyond Hoover's specifications.
  • Refrigerant check: If all above are correct and cooling is still weak, a partial refrigerant leak or internal restriction is likely. Contact a refrigeration technician for pressure testing and repair.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Condenser Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements