Possible Causes
Blown internal fuse on main PCB, Faulty power cord, Defective mains switch (if fitted), Failed main control PCB
How to Fix / Troubleshooting
Safety first: Ensure the outlet is safe and do not bypass fuses or safety devices.
Steps to diagnose no power:
- Check outlet: Test the wall socket with another appliance to confirm it has power.
- Inspect power cord: Look for visible damage. If damaged, replace with a Hoover-approved cord.
- Check mains switch: If your model has a rocker switch, ensure it is in the ON position and not loose or broken.
- Access main PCB: Remove the rear panel and inspect the main control board for a blown fuse or burn marks. Replace the fuse only with the same rating and type if you are competent to do so.
- Replace PCB: If the fuse blows again immediately or the board is visibly damaged, replace the Hoover-compatible main control PCB.