Ivation Dual-Zone Separation / Air Mixing Problem

Dual-zone wine cooler has both zones at the same temperature despite different settings.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed zone divider seal, Internal fan running continuously between zones, Control board misrouting cooling, Thermistor placement error

How to Fix / Troubleshooting

Safety: Unplug the Ivation dual-zone cooler before internal inspection.

Steps:

  • Check divider: Inspect the physical divider between upper and lower zones for gaps or missing seals. Replace any damaged Ivation zone divider gasket.
  • Verify settings: Ensure each zone is set to a different temperature and that both displays are functioning.
  • Inspect fans: Some models share cooling but use dampers or fans to direct air. Verify that dampers are not stuck open and that fans are operating as designed.

If both zones remain at the same temperature, the control board may not be regulating zones independently and may need replacement.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Zone Divider Gasket
Check Price on Amazon

We may earn a commission from links on this page.