F3
Ivation Zone Evaporator Sensor or Over-temperature Sensor Fault

Display shows F3 and one zone of the dual-zone cooler runs continuously or not at all.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective zone evaporator sensor, Sensor dislodged from evaporator, Wiring harness damage, Control board sensor input failure

How to Fix / Troubleshooting

Safety: Unplug the unit before removing interior panels.

Steps:

  • Determine affected zone: Check which zone is not cooling properly when F3 appears.
  • Access evaporator for that zone: Remove shelves and the rear interior panel for the affected zone.
  • Locate sensor: Find the small sensor clipped to the evaporator fins or tubing. Ensure it is firmly attached and wires are intact.
  • Test sensor: Measure resistance and compare to Ivation specs. Replace if faulty with an Ivation zone evaporator sensor.

If F3 persists with a good sensor, the dual-zone control board may need replacement.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Zone Evaporator Sensor
Check Price on Amazon